{"id":2513,"date":"2025-03-23T14:58:11","date_gmt":"2025-03-23T14:58:11","guid":{"rendered":"https:\/\/standard-motor-interface.com\/frequently-asked-questions\/"},"modified":"2026-05-05T12:20:16","modified_gmt":"2026-05-05T12:20:16","slug":"frequently-asked-questions","status":"publish","type":"page","link":"https:\/\/standard-motor-interface.com\/en\/frequently-asked-questions\/","title":{"rendered":"Frequently Asked Questions"},"content":{"rendered":"\n<div class=\"wp-block-cover alignwide is-light\" style=\"margin-top:0;padding-top:5vw;padding-right:0vw;padding-bottom:5vw;padding-left:0vw;min-height:519px;aspect-ratio:unset;\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-custom-light-grey-background-color has-background-dim-100 has-background-dim\"><\/span><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-f1061711 wp-block-columns-is-layout-flex\" style=\"padding-right:var(--wp--preset--spacing--20);padding-left:var(--wp--preset--spacing--20)\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-right:0;padding-left:var(--wp--preset--spacing--60);flex-basis:50%\">\n<p class=\"has-text-align-left has-black-color has-text-color has-x-large-font-size\" style=\"font-style:normal;font-weight:700;letter-spacing:-4px;line-height:0.9;text-transform:none\">Frequently Asked Questions<\/p>\n\n\n\n<div class=\"wp-block-group wp-container-content-5b91cf2b is-vertical is-nowrap is-layout-flex wp-container-core-group-is-layout-82cc2081 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-buttons is-content-justification-right is-layout-flex wp-container-core-buttons-is-layout-d445cf74 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/standard-motor-interface.com\/en\/contact\/\" target=\"_blank\" rel=\"noreferrer noopener\">Contact the office<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-right:var(--wp--preset--spacing--60);flex-basis:50%\">\n<figure class=\"wp-block-image size-large wp-duotone-varpresetduotoneduotone-1-1\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"624\" src=\"https:\/\/standard-motor-interface.com\/wp-content\/uploads\/2025\/01\/191218-Titel_smi_191217_492x300mm-1-1024x624.jpg\" alt=\"\" class=\"wp-image-177\" srcset=\"https:\/\/standard-motor-interface.com\/wp-content\/uploads\/2025\/01\/191218-Titel_smi_191217_492x300mm-1-1024x624.jpg 1024w, https:\/\/standard-motor-interface.com\/wp-content\/uploads\/2025\/01\/191218-Titel_smi_191217_492x300mm-1-400x244.jpg 400w, https:\/\/standard-motor-interface.com\/wp-content\/uploads\/2025\/01\/191218-Titel_smi_191217_492x300mm-1-300x183.jpg 300w, https:\/\/standard-motor-interface.com\/wp-content\/uploads\/2025\/01\/191218-Titel_smi_191217_492x300mm-1-768x468.jpg 768w, https:\/\/standard-motor-interface.com\/wp-content\/uploads\/2025\/01\/191218-Titel_smi_191217_492x300mm-1.jpg 1395w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div>\n<\/div><\/div>\n\n<div class=\"wp-block-group alignfull has-custom-dark-grey-color has-custom-light-grey-background-color has-text-color has-background has-link-color wp-elements-9339ffeca04407fa3c965bf3e2acd3c5 is-layout-constrained wp-container-core-group-is-layout-2df14bad wp-block-group-is-layout-constrained\" style=\"margin-top:0;margin-bottom:0;padding-top:var(--wp--preset--spacing--10);padding-right:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--10);padding-left:var(--wp--preset--spacing--50)\">\n<div class=\"wp-block-group alignfull has-base-background-color has-background is-layout-flow wp-block-group-is-layout-flow\" style=\"padding-right:var(--wp--preset--spacing--60);padding-left:var(--wp--preset--spacing--60)\">\n<hr class=\"wp-block-separator has-text-color has-base-color has-alpha-channel-opacity has-base-background-color has-background is-style-wide\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30)\"\/>\n\n\n\n<h3 class=\"wp-block-heading has-x-large-font-size\"><strong>01 Products with SMI interface<\/strong><\/h3>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading alignwide has-custom-black-color has-text-color has-link-color wp-elements-144f5f6cdcc1fd5144746d700a045044\">Is the power supply for an SMI LoVo drive defined uniformly?<\/h3>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-4cb47617d56681fe4059509b105f38db\">No. As a rule, SMI LoVo drives are supplied with 24 V DC. However, other voltages are also possible. The supply voltage of the drive and the power supply unit must be matched to each other.   <\/p>\n\n\n\n<hr class=\"wp-block-separator has-text-color has-custom-light-grey-color has-alpha-channel-opacity has-custom-light-grey-background-color has-background is-style-wide\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30)\"\/>\n\n\n\n<h3 class=\"wp-block-heading alignwide has-custom-black-color has-text-color has-link-color wp-elements-a675529db2dc01a9b79875a4acd20553\">What must be considered when replacing an SMI drive with another brand?<\/h3>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-b812a6ae9f80d3d04672af77472fbb3d\">SMI drives from different brands are compatible in terms of the interface. This means that the specified standard commands are executed in the same way on all drives and that the addressing procedures are identical.<br\/>When changing a brand or manufacturer, please note that functions, properties, and technical data of drives may differ. This includes, for example:<br\/>\u2013 maximum speed<br\/>\u2013 with or without creep speed<br\/>\u2013 with or without speed control<br\/>\u2013 adjustment procedures for end positions<br\/>\u2013 installation dimensions<br\/>\u2013 manufacturer-specific functions<br\/>\u2013 etc.   <\/p>\n\n\n\n<hr class=\"wp-block-separator has-text-color has-custom-light-grey-color has-alpha-channel-opacity has-custom-light-grey-background-color has-background is-style-wide\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30)\"\/>\n\n\n\n<h3 class=\"wp-block-heading alignwide has-custom-black-color has-text-color has-link-color wp-elements-63906e49e8e9cf686ed5904cc4432e0d\">How long is an SMI certificate valid?<\/h3>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-a1b7285334840ae4f336c9cf5e73bfd9\">A product can be considered certified as long as it is registered on the website at https:\/\/standard-motor-interface.com\/produkte\/. A certificate has been issued for these products. Products that are not registered may not be placed on the market with the SMI mark.  <\/p>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-4ed507283c7c360437d913244985d710\">If changes are made to a product or the requirements change, it may be necessary to repeat the certification process.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-text-color has-custom-light-grey-color has-alpha-channel-opacity has-custom-light-grey-background-color has-background is-style-wide\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30)\"\/>\n\n\n\n<h3 class=\"wp-block-heading alignwide has-custom-black-color has-text-color has-link-color wp-elements-85777990699e46fb9acdf9561b0ee4b9\">Where are SMI products registered?<\/h3>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-b8ccfb55a62717c24273c50523175866\">All certified products are registered on the website https:\/\/standard-motor-interface.com\/produkte\/. A data sheet can be downloaded for each product. <\/p>\n\n\n\n<hr class=\"wp-block-separator has-text-color has-custom-light-grey-color has-alpha-channel-opacity has-custom-light-grey-background-color has-background is-style-wide\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30)\"\/>\n\n\n\n<h3 class=\"wp-block-heading alignwide has-custom-black-color has-text-color has-link-color wp-elements-f240a9219ba9f5c2fe4cf4b77540a770\">What is an SMI certificate?<\/h3>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-bc2bfab589ef6120794e41236b7434db\">For products that have passed a testing and certification process, the office issues a certificate. The certificate number is listed for each product in the standardized data sheet. The certificate contains information on test reports and revision numbers of the specifications used.  <\/p>\n\n\n\n<hr class=\"wp-block-separator has-text-color has-custom-light-grey-color has-alpha-channel-opacity has-custom-light-grey-background-color has-background is-style-wide\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30)\"\/>\n\n\n\n<h3 class=\"wp-block-heading alignwide has-custom-black-color has-text-color has-link-color wp-elements-7109eeeb5de26eb1dc80d21a4b134b62\">How can I identify certified products with an SMI interface?<\/h3>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-e48d713f08e5580febd83b847805304e\">Certified products bear the SMI or SMI LoVo mark. In addition, certified products are registered on the website www.Standard-Motor-Interface.com. <\/p>\n\n\n\n<div style=\"margin-top:var(--wp--preset--spacing--10);margin-bottom:0;height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull is-layout-flow wp-block-group-is-layout-flow\" style=\"padding-right:var(--wp--preset--spacing--60);padding-left:var(--wp--preset--spacing--60)\">\n<hr class=\"wp-block-separator has-text-color has-base-color has-alpha-channel-opacity has-base-background-color has-background is-style-wide\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30)\"\/>\n\n\n\n<h3 class=\"wp-block-heading has-x-large-font-size\"><strong>02 Association SMI Standard Motor Interface e.V.<\/strong><\/h3>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading alignwide has-custom-black-color has-text-color has-link-color wp-elements-6785d992e2ea3111833efef8d0236767\">What opportunities do members of the SMI association have to participate and influence decisions?<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Members can participate in the general meetings and work in working groups.<\/li>\n\n\n\n<li>The technical working group deals with the further development of the standard and with addressing questions relating to the interface.<\/li>\n\n\n\n<li>The marketing working group promotes the dissemination of SMI.<\/li>\n<\/ul>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-5926f4b7b2407bac2f85d630dee887e2\">Participation in a working group enables an exchange of ideas within a professional network. In doing so, we ensure compliance with antitrust requirements. <\/p>\n\n\n\n<hr class=\"wp-block-separator has-text-color has-base-color has-alpha-channel-opacity has-base-background-color has-background is-style-wide\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30)\"\/>\n\n\n\n<h3 class=\"wp-block-heading alignwide has-custom-black-color has-text-color has-link-color wp-elements-a7b0aa2084a24dda77f1c3744deca2b9\">Who can become a member of SMI Standard Motor Interface e.V.?<\/h3>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-a271da7c33561e44e5fca0c92bac9ff4\">The following can be admitted as members of the association:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Suppliers of drives and controllers with an SMI interface<\/li>\n\n\n\n<li>Suppliers of roller shutter or sun shading products<\/li>\n\n\n\n<li>Planners or system integrators in the field of building automation<\/li>\n\n\n\n<li>Users, operators, or providers in the field of building automation<\/li>\n\n\n\n<li>Research institutes or associations<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-text-color has-base-color has-alpha-channel-opacity has-base-background-color has-background is-style-wide\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30)\"\/>\n\n\n\n<h3 class=\"wp-block-heading alignwide has-custom-black-color has-text-color has-link-color wp-elements-21db7fedd4c05a732ed4df5f6a75906d\">Is the Standard Motor Interface specification also accessible to non-members?<\/h3>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-74e40ae05279adeb73c16a30fec92f90\">The currently valid specification can be obtained in paper form from the office against signature of a user agreement and payment of a fee.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-text-color has-base-color has-alpha-channel-opacity has-base-background-color has-background is-style-wide\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30)\"\/>\n\n\n\n<h3 class=\"wp-block-heading alignwide has-custom-black-color has-text-color has-link-color wp-elements-85777990699e46fb9acdf9561b0ee4b9\">Where are SMI products registered?<\/h3>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-b8ccfb55a62717c24273c50523175866\">All certified products are registered on the website https:\/\/standard-motor-interface.com\/produkte\/. A data sheet can be downloaded for each product. <\/p>\n\n\n\n<hr class=\"wp-block-separator has-text-color has-base-color has-alpha-channel-opacity has-base-background-color has-background is-style-wide\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30)\"\/>\n\n\n\n<h3 class=\"wp-block-heading alignwide has-custom-black-color has-text-color has-link-color wp-elements-02b000c695ee415c7302fa940b1e2a3d\">What costs are incurred for membership and for product certification?<\/h3>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-baa51f2b6fd92129c9665c0182a3ff98\">The further development of the standard and the organization are financed through members\u2019 contributions. There is an annual fee, a trademark fee, a certification fee, and a registration fee. The fee regulations are available from the office upon request.  <\/p>\n\n\n\n<hr class=\"wp-block-separator has-text-color has-base-color has-alpha-channel-opacity has-base-background-color has-background is-style-wide\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30)\"\/>\n\n\n\n<h3 class=\"wp-block-heading alignwide has-custom-black-color has-text-color has-link-color wp-elements-b4d71a0e837a6d01cd2a10512e4b7c15\">How do you join the association SMI Standard Motor Interface e.V.?<\/h3>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-6662e2946c6260dc3fafea24239e18ad\">The steps to membership in the association SMI Standard Motor Interface e.V. are as follows:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Contact the office<\/li>\n\n\n\n<li>Complete a registration form<\/li>\n\n\n\n<li>Sign a user agreement \/ trademark agreement<\/li>\n<\/ul>\n\n\n\n<p>As a rule, the head of the office will seek a discussion with new members to get acquainted and to clarify any open questions. Corporate members receive access to the SMI documentation with updates.  <\/p>\n\n\n\n<p>After joining the association, the contributions become due in accordance with the fee regulations.<\/p>\n\n\n\n<div style=\"margin-top:var(--wp--preset--spacing--10);margin-bottom:0;height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull has-base-background-color has-background is-layout-flow wp-block-group-is-layout-flow\" style=\"padding-right:var(--wp--preset--spacing--60);padding-left:var(--wp--preset--spacing--60)\">\n<hr class=\"wp-block-separator has-text-color has-base-color has-alpha-channel-opacity has-base-background-color has-background is-style-wide\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30)\"\/>\n\n\n\n<h3 class=\"wp-block-heading has-x-large-font-size\"><strong>03 Planning, installation and commissioning<\/strong><\/h3>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading alignwide has-custom-black-color has-text-color has-link-color wp-elements-c97cdec5c2d97624b706ff8ad9ce4c9f\">Is it possible to operate more than 16 drives via an SMI interface?<\/h3>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-039b104b0225c08af49ad57133193730\">The SMI interface is designed for a maximum of 16 drives. There are also actuators or gateways that support a smaller number of drives on an SMI interface and describe this in the data sheet. If more than the permitted number of drives are connected, this can lead to malfunctions. There are also actuators or gateways that determine the number of connected drives and do not control any excess drives. Conclusion: For reliable operation, only the permitted number of drives may be connected.    <\/p>\n\n\n\n<hr class=\"wp-block-separator has-text-color has-base-color has-alpha-channel-opacity has-base-background-color has-background is-style-wide\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30)\"\/>\n\n\n\n<h3 class=\"wp-block-heading alignwide has-custom-black-color has-text-color has-link-color wp-elements-67f14636314aa0b51debd913940d13c1\">Can an SMI drive be switched off to save energy?<\/h3>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-b09f175bc856477b859e92360ebf3def\">The power consumption of a drive during idle phases can be further reduced by switching off the supply voltage. Such a procedure can be useful in commercial buildings, for example at night or on weekends. After switching back on, the drive is ready to receive a telegram after no more than 2 seconds.  <\/p>\n\n\n\n<hr class=\"wp-block-separator has-text-color has-base-color has-alpha-channel-opacity has-base-background-color has-background is-style-wide\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30)\"\/>\n\n\n\n<h3 class=\"wp-block-heading alignwide has-custom-black-color has-text-color has-link-color wp-elements-f42a23c6cedfda6f3e671d56fe3e8aba\">What must be considered when switching between push-button operation and telegram operation, or vice versa?<\/h3>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-234a13e9f1d281df14e519e5a03a224c\">SMI drives support both operating modes: push-button operation and telegram operation (see the planning manual).<\/p>\n\n\n\n<p>As soon as a drive detects a connected controller, telegram operation is activated. The drive is ready to receive commands. <\/p>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-81982650e626e3bf51cdb2c1f1ba196a\">If the controller is disconnected and push buttons are connected, the drive must switch to push-button operation in order to evaluate the push-button commands. Switching to push-button operation is not implemented in the same way for all drive brands.  <a href=\"https:\/\/standard-motor-interface.com\/faq\/#\"><\/a><\/p>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-b270dedef7ef662b018324eb480b9ae2\">The following options are available:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>The drive detects the absence of the controller and automatically switches to push-button operation<\/li>\n\n\n\n<li>The DOWN and UP buttons must be pressed once in succession<\/li>\n\n\n\n<li>The supply voltage must be briefly interrupted <\/li>\n<\/ul>\n\n\n\n<p>If the drive cannot automatically detect the absence of the controller, the procedure is described in the operating instructions.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-text-color has-base-color has-alpha-channel-opacity has-base-background-color has-background is-style-wide\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30)\"\/>\n\n\n\n<h3 class=\"wp-block-heading alignwide has-custom-black-color has-text-color has-link-color wp-elements-c09b4b22aeca5008518336897007158d\">An existing sun shading automation system is to be replaced by a controller with SMI drives. Can the existing cables continue to be used? <\/h3>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-721b4200741cc0607afeae5cea96eb34\">Conventional sun shading controllers are usually implemented with four-core cables to the drives. SMI requires a five-core cable. <\/p>\n\n\n\n<hr class=\"wp-block-separator has-text-color has-base-color has-alpha-channel-opacity has-base-background-color has-background is-style-wide\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30)\"\/>\n\n\n\n<h3 class=\"wp-block-heading alignwide has-custom-black-color has-text-color has-link-color wp-elements-fb954fb97d6e81c093a819d580d9ed19\">Are special cables required for the installation of SMI drives?<\/h3>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-18532d0294f0c12efc273453ea3dcaa3\">In residential or building installations, standardized 5-core cables can be used (NYM-J 5\u00d71.5 or NYM-J 5\u00d72.5). The conductor cross-section depends on the current requirement, the voltage drop due to cable length, and the loop resistance. The statutory installation guidelines must be observed.  <\/p>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-6d4b3da783bd79d98228a9f672fe2279\">For the installation of SMI LoVo drives, 4-core cables are required. No special requirements are specified. When dimensioning, attention must be paid to cable resistance and voltage drop, and the statutory installation regulations must be complied with.   <\/p>\n\n\n\n<hr class=\"wp-block-separator has-text-color has-base-color has-alpha-channel-opacity has-base-background-color has-background is-style-wide\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30)\"\/>\n\n\n\n<h3 class=\"wp-block-heading alignwide has-custom-black-color has-text-color has-link-color wp-elements-998871a34f111e6ac86b75a187a27437\">When connecting an SMI drive, may the phase (L) and neutral conductor (N) be swapped?<\/h3>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-7dc4a1a25b9d5d43839044d82a28114f\">The SMI drive is protected against swapping the phase (L) and neutral (N) connections and would not be damaged. However, the desired function is not guaranteed. SMI drives must be installed correctly according to the wiring diagram. Please also refer to the chapter &#8220;Installation&#8221; in the planning manual.   <\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"631\" height=\"421\" src=\"https:\/\/standard-motor-interface.com\/wp-content\/uploads\/2025\/01\/180424-Anschluesse.jpg\" alt=\"\" class=\"wp-image-174\" style=\"width:411px;height:auto\" srcset=\"https:\/\/standard-motor-interface.com\/wp-content\/uploads\/2025\/01\/180424-Anschluesse.jpg 631w, https:\/\/standard-motor-interface.com\/wp-content\/uploads\/2025\/01\/180424-Anschluesse-400x267.jpg 400w, https:\/\/standard-motor-interface.com\/wp-content\/uploads\/2025\/01\/180424-Anschluesse-300x200.jpg 300w\" sizes=\"auto, (max-width: 631px) 100vw, 631px\" \/><\/figure>\n\n\n\n<div style=\"margin-top:var(--wp--preset--spacing--10);margin-bottom:0;height:var(--wp--preset--spacing--10)\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<hr class=\"wp-block-separator has-text-color has-base-color has-alpha-channel-opacity has-base-background-color has-background is-style-wide\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30)\"\/>\n\n\n\n<h3 class=\"wp-block-heading alignwide has-custom-black-color has-text-color has-link-color wp-elements-d7069b86213534975d896c148ec87a00\">Which cable routing (topology) is possible with SMI?<\/h3>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-0f5a7a71ebc202c1fdd5bf1a05f12872\">Bus or star topology is possible; however, bus topology offers advantages in terms of wiring effort.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"450\" height=\"182\" src=\"https:\/\/standard-motor-interface.com\/wp-content\/uploads\/2025\/01\/180424-Topologien.gif\" alt=\"\" class=\"wp-image-175\" style=\"width:402px;height:auto\"\/><\/figure>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-8a6244d0256af1d148be9c6f8727b5fe\"><\/p>\n\n\n\n<div style=\"margin-top:var(--wp--preset--spacing--10);margin-bottom:0;height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull is-layout-flow wp-block-group-is-layout-flow\" style=\"padding-right:var(--wp--preset--spacing--60);padding-left:var(--wp--preset--spacing--60)\">\n<hr class=\"wp-block-separator has-text-color has-base-color has-alpha-channel-opacity has-base-background-color has-background is-style-wide\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30)\"\/>\n\n\n\n<h3 class=\"wp-block-heading has-x-large-font-size\"><strong>04 Tools for installation and testing<\/strong><\/h3>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading alignwide has-custom-black-color has-text-color has-link-color wp-elements-103772cede47e5cbc55e5ef6910431cc\">How can end positions be set on SMI drives?<\/h3>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-b6be868d9d97044165d3b888e95d661a\">Setting the end positions is the responsibility of the supplier of the roller shutter or sun shading system. The end-position setting is specific to the respective product and the drive. The end positions can be set using an adjustment cable.  <\/p>\n\n\n\n<div style=\"margin-top:var(--wp--preset--spacing--10);margin-bottom:0;height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<hr class=\"wp-block-separator has-text-color has-base-color has-alpha-channel-opacity has-base-background-color has-background is-style-wide\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30)\"\/>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull has-base-background-color has-background is-layout-flow wp-block-group-is-layout-flow\" style=\"padding-right:var(--wp--preset--spacing--60);padding-left:var(--wp--preset--spacing--60)\">\n<hr class=\"wp-block-separator has-text-color has-base-color has-alpha-channel-opacity has-base-background-color has-background is-style-wide\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30)\"\/>\n\n\n\n<h3 class=\"wp-block-heading has-x-large-font-size\"><strong>05 Addressing of SMI drives<\/strong><\/h3>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading alignwide has-custom-black-color has-text-color has-link-color wp-elements-a8a4318bafa0fabcf0c5ffefd5070e3b\">Can the KeyID be changed later?<\/h3>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-6b2fe3d423dbaf7dd6d72a540df26539\">No. Each KeyID is a uniquely assigned address from a manufacturer for the unambiguous identification of a drive. <\/p>\n\n\n\n<hr class=\"wp-block-separator has-text-color has-base-color has-alpha-channel-opacity has-base-background-color has-background is-style-wide\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30)\"\/>\n\n\n\n<h3 class=\"wp-block-heading alignwide has-custom-black-color has-text-color has-link-color wp-elements-c35f5db485d63d7094dc571a58a76a61\">How can the manufacturer code and the KeyID be entered in control systems?<\/h3>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-e06917dd71a3d65e59993bc2d6e7f997\">The manufacturer code and the KeyID uniquely define an individual drive. Both codes are documented on the drive and can be shown in decimal or hexadecimal form: <br\/><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Manufacturer code: 1..10 (decimal) or 1..A (hexadecimal)<\/li>\n\n\n\n<li>KeyID: 0..4\u2019294\u2019967\u2019295 (decimal) or 0..FFFFFFFF (hexadecimal)<\/li>\n<\/ul>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-06b9fd2165d393b26c9804994acc3141\"><br\/>Depending on the control system, the manufacturer code and the KeyID must be entered in the configuration tool. Care must be taken to enter the codes in the correct format. The KeyID can easily be converted from decimal to hexadecimal and back using a calculator in programmer mode.  <\/p>\n\n\n\n<p>There are also actuators that read the KeyID independently. The associated drives must then be assigned to the rooms afterwards. <\/p>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-23be3caa307cfe870b7413ec4f210b32\">With certain KNX actuators, the manufacturer code must first be entered in ETS and then the KeyID in the following section.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-text-color has-base-color has-alpha-channel-opacity has-base-background-color has-background is-style-wide\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30)\"\/>\n\n\n\n<h3 class=\"wp-block-heading alignwide has-custom-black-color has-text-color has-link-color wp-elements-017d02426a02c618fc207c5b785a7d6d\">What addresses does a drive have?<\/h3>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-8068b6bffcfa2342e9222e22b30cb49f\">A drive has three codes for identification:<\/p>\n\n\n\n<p>The KeyID is a 32-bit address. Each KeyID is assigned only once by a manufacturer. <\/p>\n\n\n\n<p>The manufacturer code is a code in the range 0..10. Together with the KeyID, the manufacturer code identifies a single drive, which occurs only once in this combination. <\/p>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-9d9b1583842cd4746fc18263e4bdd038\">The slave address is a code in the range 0..15 and can be assigned to each drive as a short address.<\/p>\n\n\n\n<div style=\"margin-top:var(--wp--preset--spacing--10);margin-bottom:0;height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull has-custom-light-grey-background-color has-background is-layout-flow wp-block-group-is-layout-flow\" style=\"padding-right:var(--wp--preset--spacing--60);padding-left:var(--wp--preset--spacing--60)\">\n<hr class=\"wp-block-separator has-text-color has-base-color has-alpha-channel-opacity has-base-background-color has-background is-style-wide\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30)\"\/>\n\n\n\n<h3 class=\"wp-block-heading has-x-large-font-size\"><strong>06 Faults<\/strong><\/h3>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading alignwide has-custom-black-color has-text-color has-link-color wp-elements-b610d0b90e5a99d92e84626ea873da68\">Individual drives or a group do not execute travel commands correctly<\/h3>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-82cd4563b45a5eebdb3fe4e6513cd587\">The cause may be an installation error. The correct connection of the power supply must be checked. For STAS4 plug connections, L must be connected to terminal 3 and N to terminal 4. Swapping the connections can lead to malfunctions with longer cable runs.   <\/p>\n\n\n\n<hr class=\"wp-block-separator has-text-color has-base-color has-alpha-channel-opacity has-base-background-color has-background is-style-wide\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30)\"\/>\n\n\n\n<h3 class=\"wp-block-heading alignwide has-custom-black-color has-text-color has-link-color wp-elements-a196625124c4fcbdc67ad725900c887d\">Position query does not work for a group of drives<\/h3>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-f90541bb8317b891b5bdbc659b851ceb\">If two or more drives have the same slave address, travel commands work without problems. Read commands, such as reading out the current position, are not possible with such a configuration. For correct use of read commands, each drive must be programmed with its own slave address. The assignment of the slave address is provided via the SMI-easyMonitor program or via actuators. Drives with different slave addresses can be combined into groups using the group key.    <\/p>\n\n\n\n<hr class=\"wp-block-separator has-text-color has-base-color has-alpha-channel-opacity has-base-background-color has-background is-style-wide\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30)\"\/>\n\n\n\n<h3 class=\"wp-block-heading alignwide has-custom-black-color has-text-color has-link-color wp-elements-657678c4155cef30b7efe6b09f4d1889\">Can one drive be used as a reference drive to control a group of venetian blinds?<\/h3>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-7718c5801d2405ae356832287c1543c0\">When controlling venetian blinds, one drive could be used as a reference drive to monitor an end-position. When the reference drive reaches the end position, all other drives are stopped. This approach is not recommended, as 230 VAC drives may have slightly different run times.  <\/p>\n\n\n\n<hr class=\"wp-block-separator has-text-color has-base-color has-alpha-channel-opacity has-base-background-color has-background is-style-wide\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30)\"\/>\n\n\n\n<h3 class=\"wp-block-heading alignwide has-custom-black-color has-text-color has-link-color wp-elements-0a69f2c87d1631b5da43e9b60fb0232b\">SMI-easyMonitor<\/h3>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-0042fd3395d240265eb0ef19b9fde0e7\">When using SMI-easyMonitor, faults may occur if:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Antivirus programs on the PC interfere with the process -&gt; disable the virus scanner<\/li>\n\n\n\n<li>the PC\u2019s processing power is insufficient -&gt; use a different PC<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-text-color has-base-color has-alpha-channel-opacity has-base-background-color has-background is-style-wide\" style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30)\"\/>\n\n\n\n<h3 class=\"wp-block-heading alignwide has-custom-black-color has-text-color has-link-color wp-elements-158ef65d77b3e6e5796338b384a7e9ba\">What reasons can lead to different slat positions in a group of venetian blinds?<\/h3>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-1e93f3753abb71aad59d2763cae7f04c\">With SMI drives, the slats of a venetian blind can be aligned precisely. If the slats are not aligned as desired, the following causes may apply: <\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>the tilt gearboxes of the venetian blinds are unsuitable for precise slat positioning<\/li>\n\n\n\n<li>the end positions are not set correctly<\/li>\n\n\n\n<li>the slat is adjusted in many small steps and the steps are too small for reproducible slat positioning<\/li>\n\n\n\n<li>the control commands for the venetian blinds differ due to the algorithms used <\/li>\n<\/ul>\n\n\n\n<p class=\"has-contrast-1-color has-text-color has-link-color wp-elements-cc2115f87168b9844960fc5b80130434\">-&gt; analysis using SMI-easyMonitor<\/p>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>01 Products with SMI interface Is the power supply for an SMI LoVo drive defined uniformly? No. As a rule, SMI LoVo drives are supplied with 24 V DC. However, other voltages are also possible. The supply voltage of the drive and the power supply unit must be matched to each other. What must be [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-2513","page","type-page","status-publish","hentry"],"blocksy_meta":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Frequently Asked Questions - SMI Standard Motor Interface e.V.<\/title>\n<meta name=\"description\" content=\"In our SMI Frequently Asked Questions, you will find answers on the SMI interface, drives, certification, and SMI installation.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/standard-motor-interface.com\/en\/frequently-asked-questions\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Frequently Asked Questions - SMI Standard Motor Interface e.V.\" \/>\n<meta property=\"og:description\" content=\"In our SMI Frequently Asked Questions, you will find answers on the SMI interface, drives, certification, and SMI installation.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/standard-motor-interface.com\/en\/frequently-asked-questions\/\" \/>\n<meta property=\"og:site_name\" content=\"SMI Standard Motor Interface e.V.\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-05T12:20:16+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/standard-motor-interface.com\/wp-content\/uploads\/2025\/01\/191218-Titel_smi_191217_492x300mm-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1395\" \/>\n\t<meta property=\"og:image:height\" content=\"850\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"9 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/standard-motor-interface.com\\\/en\\\/frequently-asked-questions\\\/\",\"url\":\"https:\\\/\\\/standard-motor-interface.com\\\/en\\\/frequently-asked-questions\\\/\",\"name\":\"Frequently Asked Questions - SMI Standard Motor Interface e.V.\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/standard-motor-interface.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/standard-motor-interface.com\\\/en\\\/frequently-asked-questions\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/standard-motor-interface.com\\\/en\\\/frequently-asked-questions\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/standard-motor-interface.com\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/191218-Titel_smi_191217_492x300mm-1-1024x624.jpg\",\"datePublished\":\"2025-03-23T14:58:11+00:00\",\"dateModified\":\"2026-05-05T12:20:16+00:00\",\"description\":\"In our SMI Frequently Asked Questions, you will find answers on the SMI interface, drives, certification, and SMI installation.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/standard-motor-interface.com\\\/en\\\/frequently-asked-questions\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/standard-motor-interface.com\\\/en\\\/frequently-asked-questions\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/standard-motor-interface.com\\\/en\\\/frequently-asked-questions\\\/#primaryimage\",\"url\":\"https:\\\/\\\/standard-motor-interface.com\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/191218-Titel_smi_191217_492x300mm-1-1024x624.jpg\",\"contentUrl\":\"https:\\\/\\\/standard-motor-interface.com\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/191218-Titel_smi_191217_492x300mm-1-1024x624.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/standard-motor-interface.com\\\/en\\\/frequently-asked-questions\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Start\",\"item\":\"https:\\\/\\\/standard-motor-interface.com\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Frequently Asked Questions\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/standard-motor-interface.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/standard-motor-interface.com\\\/en\\\/\",\"name\":\"SMI Standard Motor Interface e.V.\",\"description\":\"Die einheitliche bidirektionale Schnittstelle f\u00fcr elektrische Antriebe in Rollladen- und Sonnenschutzanlagen\",\"publisher\":{\"@id\":\"https:\\\/\\\/standard-motor-interface.com\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/standard-motor-interface.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/standard-motor-interface.com\\\/en\\\/#organization\",\"name\":\"SMI Standard Motor Interface e.V.\",\"url\":\"https:\\\/\\\/standard-motor-interface.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/standard-motor-interface.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/standard-motor-interface.com\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/SMI_ohne_Text_TransparenterHintergrund.png\",\"contentUrl\":\"https:\\\/\\\/standard-motor-interface.com\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/SMI_ohne_Text_TransparenterHintergrund.png\",\"width\":297,\"height\":167,\"caption\":\"SMI Standard Motor Interface e.V.\"},\"image\":{\"@id\":\"https:\\\/\\\/standard-motor-interface.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Frequently Asked Questions - SMI Standard Motor Interface e.V.","description":"In our SMI Frequently Asked Questions, you will find answers on the SMI interface, drives, certification, and SMI installation.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/standard-motor-interface.com\/en\/frequently-asked-questions\/","og_locale":"en_US","og_type":"article","og_title":"Frequently Asked Questions - SMI Standard Motor Interface e.V.","og_description":"In our SMI Frequently Asked Questions, you will find answers on the SMI interface, drives, certification, and SMI installation.","og_url":"https:\/\/standard-motor-interface.com\/en\/frequently-asked-questions\/","og_site_name":"SMI Standard Motor Interface e.V.","article_modified_time":"2026-05-05T12:20:16+00:00","og_image":[{"width":1395,"height":850,"url":"https:\/\/standard-motor-interface.com\/wp-content\/uploads\/2025\/01\/191218-Titel_smi_191217_492x300mm-1.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"9 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/standard-motor-interface.com\/en\/frequently-asked-questions\/","url":"https:\/\/standard-motor-interface.com\/en\/frequently-asked-questions\/","name":"Frequently Asked Questions - SMI Standard Motor Interface e.V.","isPartOf":{"@id":"https:\/\/standard-motor-interface.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/standard-motor-interface.com\/en\/frequently-asked-questions\/#primaryimage"},"image":{"@id":"https:\/\/standard-motor-interface.com\/en\/frequently-asked-questions\/#primaryimage"},"thumbnailUrl":"https:\/\/standard-motor-interface.com\/wp-content\/uploads\/2025\/01\/191218-Titel_smi_191217_492x300mm-1-1024x624.jpg","datePublished":"2025-03-23T14:58:11+00:00","dateModified":"2026-05-05T12:20:16+00:00","description":"In our SMI Frequently Asked Questions, you will find answers on the SMI interface, drives, certification, and SMI installation.","breadcrumb":{"@id":"https:\/\/standard-motor-interface.com\/en\/frequently-asked-questions\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/standard-motor-interface.com\/en\/frequently-asked-questions\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/standard-motor-interface.com\/en\/frequently-asked-questions\/#primaryimage","url":"https:\/\/standard-motor-interface.com\/wp-content\/uploads\/2025\/01\/191218-Titel_smi_191217_492x300mm-1-1024x624.jpg","contentUrl":"https:\/\/standard-motor-interface.com\/wp-content\/uploads\/2025\/01\/191218-Titel_smi_191217_492x300mm-1-1024x624.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/standard-motor-interface.com\/en\/frequently-asked-questions\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Start","item":"https:\/\/standard-motor-interface.com\/en\/"},{"@type":"ListItem","position":2,"name":"Frequently Asked Questions"}]},{"@type":"WebSite","@id":"https:\/\/standard-motor-interface.com\/en\/#website","url":"https:\/\/standard-motor-interface.com\/en\/","name":"SMI Standard Motor Interface e.V.","description":"Die einheitliche bidirektionale Schnittstelle f\u00fcr elektrische Antriebe in Rollladen- und Sonnenschutzanlagen","publisher":{"@id":"https:\/\/standard-motor-interface.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/standard-motor-interface.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/standard-motor-interface.com\/en\/#organization","name":"SMI Standard Motor Interface e.V.","url":"https:\/\/standard-motor-interface.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/standard-motor-interface.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/standard-motor-interface.com\/wp-content\/uploads\/2025\/01\/SMI_ohne_Text_TransparenterHintergrund.png","contentUrl":"https:\/\/standard-motor-interface.com\/wp-content\/uploads\/2025\/01\/SMI_ohne_Text_TransparenterHintergrund.png","width":297,"height":167,"caption":"SMI Standard Motor Interface e.V."},"image":{"@id":"https:\/\/standard-motor-interface.com\/en\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/standard-motor-interface.com\/en\/wp-json\/wp\/v2\/pages\/2513","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/standard-motor-interface.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/standard-motor-interface.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/standard-motor-interface.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/standard-motor-interface.com\/en\/wp-json\/wp\/v2\/comments?post=2513"}],"version-history":[{"count":1,"href":"https:\/\/standard-motor-interface.com\/en\/wp-json\/wp\/v2\/pages\/2513\/revisions"}],"predecessor-version":[{"id":2514,"href":"https:\/\/standard-motor-interface.com\/en\/wp-json\/wp\/v2\/pages\/2513\/revisions\/2514"}],"wp:attachment":[{"href":"https:\/\/standard-motor-interface.com\/en\/wp-json\/wp\/v2\/media?parent=2513"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}